administration student task rubric student work technical quality
 
NCTM Activity - Soil Temperature
Task with Student Directions

GLOBE Assessment
Grade 5-8

Math Activity for Protocol Test

The GLOBE protocol tells you to take the 1st soil temp measurement at 2 minutes and then repeat the measurements at 1 minute intervals until consecutive reading are 0.5 - 1.0 degrees C. How long did it take for the thermometer to accurately record the soil temperature?

temp at 2 min = 14.5 degrees C
temp at 3 min = 15.6 degrees C
temp at 4 min = 15.9 degrees C
temp at 5 min = 16.0 degrees C

NCTM Standard: data analysis & probability 3.1

Soil Temperature Protocol Test

The Soil Temperature protocol test assesses students' ability to select a site, prepare and calibrate a thermometer, and to accurately collect soil temperature data.

Download a Word or pdf copy.

 

Soil Temperature Protocol Test

 

 

 students-->

Student activity & Level of Performance

+ appropriate student performance

- inappropriate student performance

n.a. not appropriate or not observed

                                           
Select a Site                                            
Select relatively flat, non compacted sunny area - 5 m diameter w/ uniform characteristics                                            
Note if it has rained with past 24 hours                                            
Preparation & Calibration                                            
Insert thermometer into wooden block so 7 cm extends beyond bottom of block                                            
Calibrate thermometer using atmosphere calibration thermometer                                            
If > 2° C difference reset thermometer per manufacturer's directions                                            
Soil Temperature Measurements                                            
Make pilot hole 5cm deep using nail                                            
Remove nail using twisting motion                                            
If ground cracks / bulges, move 25 cm; retry                                            
Insert thermometer into block to 7 cm                                            
Insert block + thermometer into pilot hole                                            
Record temp at 2 min.; repeat at 1 min. intervals until consecutive reading are 0.5 - 1.0° C; record on data sheet                                            
Remove block + thermometer using twisting motion; remove thermometer from block                                            
Insert thermometer into pilot hole to 12 cm.                                            
Record temp after 2 minutes; repeat at 1 minute intervals until consecutive reading are 0.5 - 1.0° C; record on data sheet                                            

 


©1997-2005 SRI International. All rights reserved. Terms of Use